Elevator Information

STATE ID
StateId
3015
UNIT STATUS & INSPECTION AGENCY
Status
Active
Inspected By
State of Ohio
LOCATION
Address
AKRON U POLSKY BUILDING (ELEV)
225 S MAIN ST
AKRON 44308
OWNER
OwnerAddress
UNIVERSITY OF AKRON PFOC
146 HILL ST
AKRON OH44325-0401
UNIT INFO
Elevator Type
Passenger
ASME
S01 Ohio Red Book (01/01/1901)-(03/30/1974)
Power Type
ELECTRIC DRUM/TRACT (E)
Capacity (lbs)
4000
Manufacturer Name
OTIS ELEVATOR COMPANY
Speed of Car
450
Total Travel (ft)
72
Total Number of Floor(s) Served
6
Building Name
AKRON U POLSKY BUILDING
Local ID
POL 3
SAFETY TEST INFO
Last Load Test
01/30/2023
Last Safety Test
01/30/2023
CERTIFICATE INFO
Expiration Date
07/31/2025
Plan Review Date
07/17/2015
INSPECTION INFO
Last Annual Date
06/30/2010
Last Semi Date
02/07/2025
LAST INSPECTION RESULTS
Date of last Inspection: 02/07/2025
M 006 - BEING REPAIRED - This unit was not in operating condition at the time of the inspection. This unit is required to be inspected once the unit is returned to operational status. The elevator device is subject to continued invoices from our office unless the elevator device is properly removed from service and properly sealed. Please contact our scheduling office to arrange for an inspection at 614-644-2223 or elevators@com.ohio.gov.

INSTALLATION INFO
Installer Name
OTIS ELEVATOR COMPANY
Install Date
07/22/1940
PERMIT INFO
Permit Number
8334282
Permit Date
05/09/2025
Permit Type
Alteration/Repair
Scope of Work
New gearless machine, controller, cab interior, car & HW doors, car and HW tracks/locks/hangers, door operator, car & cwt roller guides, governor, safeties, fixtures, buffers, CWT