Elevator Information

STATE ID
StateId
41533
UNIT STATUS & INSPECTION AGENCY
Status
Active
Inspected By
State of Ohio
LOCATION
Address
CANAL SIDE
354 S MAIN ST
AKRON 44311
OWNER
OwnerAddress
CRUCS INVESTMENT GROUP
2257 JUMPER KNOLL DR MEDINA OH44256
UNIT INFO
Elevator Type
Passenger
ASME
S12 ASME A17.1b 1995 (08/01/1996)-(03/31/1999)
Power Type
HYDRAULIC DIRECT (H)
Capacity (lbs)
2500
Manufacturer Name
AKRON
Speed of Car
125
Total Travel (ft)
28
Total Number of Floor(s) Served
4
Building Name
CANAL SIDE
Local ID
1
SAFETY TEST INFO
Last Load Test
N/A
Last Safety Test
07/03/2024
CERTIFICATE INFO
Expiration Date
07/31/2025
Plan Review Date
01/28/1999
INSPECTION INFO
Last Annual Date
01/23/2012
Last Semi Date
03/06/2025
LAST INSPECTION RESULTS
Date of last Inspection: 03/06/2025
M 016 - RESTORE EQUIPMENT TO ORIGINAL CODE - Shall repair equipment according to the code under which it was installed. See ASME A17.1 - 8.6 ( unit low on hydraulic oil, cavitating going into the top floor ) ( 3/6/25 )

MR 021 - ABC FIRE EXTINGUISHER - A properly tested and maintained ABC type fire extinguisher of adequate size shall be provided in the machine rooms, control rooms, and machinery spaces and control spaces per ASME A17.1-8.6.1.6.5. The fire extinguisher in the machine rooms, control rooms, and machinery spaces and control spaces is to be of sufficient size to allow workers within the room to exit safely in the case of a fire within the machine rooms / control rooms occurs during their maintenance procedures. The extinguisher is not meant for usage for returning to the room to fight the fire. The extinguisher is to be located in an area of the room that will allow easy access to the extinguisher by workers. It is recommended that when possible, the extinguisher be located near the jamb side of the elevator room entrance door. ( last inspected Feb 2016 ) ( 3/6/25 )

EC 011 - RESTORE OR INCREASECAR LIGHTING - Shall restore or increase car lighting per ASME A17.1-2.14.7. ( 3/6/25 )

R 001 - FIRE FIGHTERS EMERGENCY OPERATION LOG - All elevators provided with Firefighters Emergency Operation shall be subjected monthly, by authorized personnel, to Phase I recall by use of the key switch, and a minimum of one-floor operation on Phase II. Deficiencies shall be corrected. A record of findings shall be available to elevator personnel and the authority having jurisdiction per ASME A17.1-8.6.11.1. ( last logged test date 5/16/23 ) ( 6/14/24 )

EC 028 - CAR DOOR RESTRICTORS - For elevators installed under the 1980 edition of ASME A17.1 and later, means shall be provided to restrict the opening of the car doors outside the landing zone per ASME A17.1-2.14.5.7.(*3-22-22*) ( 6/14/24 )

INSTALLATION INFO
Installer Name
AKRON
Install Date
01/25/1999
PERMIT INFO
Permit Number
4460688
Permit Date
05/09/2014
Permit Type
Alteration/Repair
Scope of Work
Replacing old 120v elevator recall system. Run all new wiring and new control panel & smokes.